4.5″ Deep Cellular Roof Deck

A 4.5″-deep cellular roof deck — corrugated steel with a flat plate welded underneath. Built for long spans and significant loads, it presents a clean, finished ceiling below. Available in multiple gauge combinations, galvanized or paint-ready — and manufactured to any length you need.
Cordeck Metal Roof Deck Products
Cordeck Metal Roof Deck Specs
At-a-glance specs

Standard Cover Width

24"

Available Gauges

20/20, 18/20, 18/18, 16/18, 16/16

Available Finishes

Galvanized-G90, Galvanized-G90-Prime-able

Compliance

SDI · UL · FM Approved

Cordeck's 4.5″ Deep Cellular Roof Deck welds a flat steel sheet beneath a corrugated deck to create deep, enclosed cellular raceways. At 4.5″, it reaches well across open bays and carries heavy roof loads, and its flat underside gives large spaces a clean, finished ceiling — one whose cells can carry batt or closed-cell sound absorption, with acoustical perforations available. Cordeck manufactures it to SDI standards, with engineering and project-management support — AutoCAD drawings, bundle placement plans, and cut-to-length sizing.

Quick Quote

Reply in under 1 business hr

Not sure exactly what you need? Send the basics and our team follows up fast. Know exactly what you need? Use our detailed quote form.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Gauge
(optional)
(optional)
sheets, optional
optional

Prefer to talk it through? Give us a call 877.857.6400

Same-day pickup

From any of our 8 locations

Fast delivery

Coast to coast, all 50 states

Excellent service

Family-business attention to every order

Need it tomorrow? Call 877.857.6400

Applications & use cases

Where 4.5″ Deep Cellular Roof Deck Shows Up

A long-span structural roof for large venues that need a finished ceiling — university arenas and fieldhouses, regional convention centers, major performing-arts venues, and large warehouse roofs. Its acoustical option also suits Olympic-size natatoriums, large exhibit halls, and airport terminal canopy sections.

Primary Applications

Structural roof substrate with enclosed cellular raceway

4.5" deep profile for long-span applications requiring significant load capacity

Flat steel bottom plate welded to corrugated deck

Installed over structural steel for insulation, weatherproofing, and roofing materials

Common Examples
  • Large university arena or fieldhouse roofs
  • Regional convention center roofs
  • Major performing arts venue roofs
  • Large warehouse roofs where a finished ceiling is required
Secondary Applications

Mezzanine and canopy construction

Flat underside for exposed open ceiling design

Enclosed cells house sound-absorbing material (batt or closed cell)

Available with acoustical perforations for noise attenuation in gymnasiums, auditoriums, and natatoriums

Floating clip insulation option for post-painting

Common Examples
  • Olympic-size indoor swimming facility ceiling with acoustical treatment
  • Large exhibit hall with exposed painted deck ceiling
  • Airport terminal canopy roof sections
Engineering data

Load Tables & Section Properties

SDI-compliant uniform load values and section properties. Download the full data sheet or review the tables below.

Uniform Load Table

Cordeck 4.5 Cellular Roof Deck Uniform Load Table

Section Properties

Product Information

Specifications & Documentation

  1. Cordeck certifies that our Cellular Roof Deck has been evaluated in accordance with the applicable SDI Standards and property values for the Uniform Load Tables, and meets or exceeds SDI requirements.
  2. Load shown in tables is uniformly distributed total (dead plus live) load in psf (kPa). Loads in shaded areas are governed by live load deflection not in excess of L/240, the dead load included in 10 psf (0.478.kPa). All loads are governed by the allowable flexural stress limit of 20 ksi (140 Mpa) maximum yield steel. Where heavy construction loads or other unusual concentrated loads are anticipated during the lifetime of the deck, the specified live load must be increased to offset the effects of the abnormal concentrated load. See Maximum Spans for Construction and Maintenance Loads in the SDI Design Manual.
  3. The rib width limitations shown are taken at the theoretical intersection points of the flange and web projections. Depending on the radius used, the load table could vary from that shown.
  4. Span length assumes center to center spacing of supports. Tabulated loads shall not be increased by assuming clear span dimensions.
  5. The sectional properties for Cordeck Cellular Roof Deck have been evaluated with the latest edition of the American Iron and Steel Institute (AISI) Specification for the Design of Cold-Formed Steel Structural Members.
  6. Bending moment formula used for flexural stress and deflection limitations in accordance with Steel Deck Institute are:
  7. Cordeck guarantees that our Cellular Roof Deck conforms to the Roof Deck Specifications of the Steel Deck Institute and the dimensional parameters established for the load table.
  1. Certification
    1. Steel roof deck will be Cellular Roof Deck as manufactured by Cordeck from steel conforming to ASTM A653 for galvanized deck or ASTM A1008-00 Grade 33 for cold rolled prime painted steel.
  2. Prime Painted
    1. Roof deck shall receive one coat of standard gray primer paint over cleaned and pretreated steel.
    2. The primer coat is intended to protect the steel for only a reasonably short period of exposure, in normal atmospheric conditions, and shall be considered an impermanent and provisional coating.
    3. Field painting of prime painted material is recommended especially where the deck is exposed.
  3. Galvanized
    1. All steel shall be coated to conform to ASTM A924 G-60 or G-90 or to Federal Specification QQ-S-775.
    2. Galvanized finish in G-60 or G-90 coating is desirable in high moisture atmospheric conditions.
    3. Cordeck shall not be responsible for the cleaning of the underside of steel deck to ensure bond of fireproofing. Adherence of fireproofing material is dependent on many variables. The adhesion ability of fireproofing materials is the responsibility of the fireproofing applicator.
  4. Accessories
    1. Cordeck can supply ridge & valley plates, cant strips, finish strips, sump pans, end & side closures, pour stops, deck plate, rubber cell closures, screws and other accessories needed to complete the project.
  1. All steel deck material is manufactured by SDI members or manufactured in accordance to SDI.
  2. Cordeck certifies that all material will be in accordance with the SDI Cellular Deck Manual specifications.
  3. Cordeck Cellular Roof Deck conforms to all applicable SDI Cellular Deck Manual Specifications.
  1. Cordeck Steel Cellular Roof Deck shall be installed by qualified and experienced workers.
  2. Roof deck installation drawings shall be submitted to the project architect and engineer for approval prior to the manufacture of materials.
  3. Steel roof deck shall be placed in accordance with approved erection drawings.
  4. End laps shall be a nominal 2” and positioned over supports.
  5. Position each deck unit on a supporting structural frame. Adjust to final position with accurately aligned side laps and ends bearing on supporting members. On joist framing, be sure the appropriate end laps occur over a top chord angle for proper anchorage.
  6. When one row is placed end to end, begin another, making alignment adjustment if necessary.
  7. Each deck unit shall be placed on supporting steel framework and adjusted to final positions before permanently fastened. Do not use unfastened deck as a working platform or storage area.
  8. Cutting of openings through the deck and all skew cutting shall be performed in the field. Openings not shown on the erection drawings such as those required for stack, conduits, plumbing, vents, etc., shall be cut, and reinforced if necessary, in accordance with SDI.
  1. Roof deck sheets shall be attached as soon as possible after placement. All sheets placed shall be attached prior to the end of each work day. Arc welding is the most commonly used method for attaching Cordeck Steel Cellular Roof Deck to structural supports. Welder shall immediately follow the placement crew.
  2. All welds are to be made from the top of the deck down through the bottom flange of the ribs. Welds shall penetrate and attach all thicknesses of material to the structural supports.
  3. Caution shall be exercised on the selection of the electrodes to provide positive attachment and to prevent high amperage blow holes.
  4. Puddle welds shall be at least 5/8” diameter or elongated puddle welds with an equal perimeter. Fillet welds, when used, shall be at least 1” long.
    1. Cellular Roof Deck ends shall be welded to structural supports at 12” on center maximum and 18” on center maximum at intermediate supports or as indicated on erection drawings.
    2. Various mechanical fastening systems other than welding are recognized as viable anchoring methods provided they are reviewed, approved, or specified by the project designer. These include but are not limited to power-activated or pneumatically driven fasteners and screws.
    3. When spans exceed 5’-0”, side laps shall be fastened together at a maximum spacing of 36 inches on center or as indicated on erection drawings.

Attachment must be determined by the designer as part of the overall building design process. Values given in this document are adequate in most cases.

  1. Protect steel deck from corrosion, deformation, and other damage during storage, handling, and installation.
  2. Deck not promptly erected shall be stored off the ground, with one end elevated to provide drainage. Bundles must be protected against condensation with a ventilated waterproof covering.
  3. Bundles must be stacked so there is no danger of shifting or material damage. Bundles must be checked for tightness, and retightened as necessary.
  4. Deck bundles on the building frame must always be placed near a main supporting beam, at a column, or a wall. In no situation are the bundles to be placed on unbolted frames or unattached and unbridged joists. The structural frame must be properly braced to receive the bundles.
Features & benefits

Why Contractors Choose Cordeck

Project management and engineering services are offered by Cordeck’s full, expert, in-house engineering and detailing services to assure optimal planing and design. Our experienced engineers and technicians provide individual customer service and attention to detail from concept to completion.

SDI Membership by the manufacturer guarantees product quality in accordance to the Steel Deck Institute (SDI).

AutoCAD® drawings can be transferred electronically for improved quality and reduced time and cost of drawing transmittal.

Bundle Placement plans are provided to ensure correct location of bundles during unloading and hoisting to steel framework.

On-spec, guaranteed quality. Our production staff are true craftsmen, not just interested in getting the job done, but in doing it perfectly.

Knowledgeable, courteous, caring employees throughout our ranks. We’re a “family business”…no “big corporate” attitude here! We genuinely appreciate our customers’ patronage and trust, handling every order, regardless of size, with utmost care and attention.

Complete the job

Decking Accessories & Fasteners

Let Cordeck be your one-stop shop. Our complete inventory of steel flat stock lets us produce the accessories you need, stocked and shipped alongside your B Deck order so nothing holds up the install.
  • Img Product Sump Pan

    Sump Pan

    The Sump Pan is a roof deck accessory that is designed to work with roofs drainage system.

  • Img Product Pour Stop 150x150 1

    Pour Stop

    A Pour Stop, also known as screed angle or bent plate, is an angled piece of steel, used to contain concrete being poured within a perimeter of metal decking.

  • Channel Closure

    Channel Closure

    Channel Closures are designed to close off an area around a channel before the concrete is poured.

  • Img Product Side Closure

    Side Closure

    A Side Closure closes open ends of metal floor deck, preventing concrete from spilling through the ends of decking.

  • Img Product J Closure

    J Closure

    J Closures are meant to be fastened to the open ends metal decking to achieve a tight fitting closure and support.

  • Column Closure

    Flat Plate

    Column Closures are designed to close off an area around a column before the concrete is poured.

  • Filler Strip

    Finish Strip

    Finish Strips are designed to close gaps between the weak end of the metal deck and the adjacent beam. It also prevents poured concrete from falling through the gaps.

  • Img Product Valley Plate 300x147 1

    Valley Plate

     A Valley Plate protects the meeting edges of two metal deck sheets. 

  • Img Product Ridge Plate

    Ridge Plate

    The Ridge Plate is a piece of trim that is installed at the peak of the roof. It Protects the gap at the peak where both slopes meet.

  • End Closure

    End Closure

    An End Closure is a metal deck floor accessory that is placed over the ends of deck to prevent concrete, water, or even sound from leaking out of the deck flutes.

  • Img Product Z Closure

    Z Closure

    Z Closures are meant to be fastened to the open ends metal decking to achieve a tight fitting closure and support.

  • Img Product Std Mid Pan Screw

    Standard Mid Span Screws

  • Img Product Heavy Duty Fasteners

    Heavy Duty Self Drilling Fasteners

  • Cordeck Metal Weld Washer

    Weld Washer

    Weld Washers prevent holes while welding metal deck. These small pieces of galvanized steel are designed with a small curved to fit into the valley of metal decking.

  • Cordecks Rubber Closure Topside Strip

    Rubber Closures – Topside Strips

    Rubber Closures seal the ridge cap, protecting the metal deck from moisture.

  • Cordecks Rubber Closure Topside Plug

    Rubber Closures – Topside Plugs

    Rubber Closures seal the ridge cap, protecting the metal deck from moisture.

  • Cordecks Rubber Closure Underside Strip

    Rubber Closures – Underside Strips

    Rubber Closures seal the ridge cap, protecting the metal deck from moisture.

  • Cordecks Rubber Closure Underside Plug

    Rubber Closures – Underside Plugs

    Rubber Closures seal the ridge cap, protecting the metal deck from moisture.

What our customers say

"I just wanted to say thank you for expediting my order. We got the decking at 6:30 this morning and my customer was thrilled. Your customer service is outstanding. I appreciate it and look forward to working together again."

Jordan Nass, Precision Building Solutions